All Specification Requests
Open for proposals
Buyer details protected
False Ceiling

SR-2026-00242

False Ceiling

False ceiling for

Share:

Project context

PRJ-FA574F5C81CA

3 more open requirements in this project

Project type
MLCP
Project size
25,000–50,000 sq ft

Client, architect and exact address stay hidden.

Browse all 4 requirements
Delivery location
Not specified
Proposal deadline
Open until buyer closes
BOQ lines
3 specified items
Reference pack
No files supplied
Buyer-supplied reference for False Ceiling

Reference image

Added by the professional to show what they have in mind.

BOQ preview

Items requested for specification

3 buyer-supplied lines

Quantities and reference-file availability are shown as supplied. Sign in to unlock technical notes and protected files. Buyer budget stays private.

C-04: Toilets, janitor rooms, handwash Supply and fixing 8mm hilux butt edge tile false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of shillouttee main ‘T’ runner suitably spaced at joints to get required length and of size 15x42 mm made from 0.30 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 15x32 mm made out of 0.30 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 15 x 32 mm made of 0.30 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm) made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying tile in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using slotted cleats of size 25x35x1.6 mm fixed to ceiling with 8 mm dia and 45 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 15 mm of all T Sections shall be pre-painted with polyester baked paint. calcium silicate board tile made with Calcareous & Siliceous materials reinforced with cellulose fibre manufactured through autoclaving process to give stable crystalline structure of size 595x595 mm. 8mm thick Ramco Hilux Calcium silicate designer Tile-Tiny star System Performance: Classification of Fire Performance (EN-13501-1)- ClassA1, Smoke Developed Index (ASTM-E90)- Class O, Water Resistant, Termite & Fungal resistance, Sound Insulation (ASTM E 413)(STC and NRC) and Durability (EN12467)-All Weather Conditions , Lower Thermal Conductivity, Low Dry wet Shrinkage and Robustness.

205 sqm

Technical notes unlock after sign-in

C-01: Entrance lobby, all floors Providing and Fixing 15 mm thick densified Micro edge, eco-friendly light weight calcium silicate false ceiling tiles with Anti-Microbial Bio-coated of approved texture skydots of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of shillouttee main ‘T’ runner suitably spaced at joints to get required length and of size 15x42 mm made from 0.30 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 15x32 mm made out of 0.30 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 15 x 32 mm made of 0.30 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm) made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying tile in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using slotted cleats of size 25x35x1.6 mm fixed to ceiling with 8 mm dia and 45 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 15 mm of all T Sections shall be pre-painted with polyester baked paint. System Performance: NRC value of 0.20 (Minimum), light reflection > 85%, 100% humidity resistance and also having thermal conductivity <0.043 w/m 0 KC.

217 sqm

Technical notes unlock after sign-in

C-05: Entrance canopy Providing and Fixing 15 mm thick densified Micro edge, eco-friendly light weight calcium silicate false ceiling tiles with Anti-Microbial Bio-coated of approved texture skydots of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of shillouttee main ‘T’ runner suitably spaced at joints to get required length and of size 15x42 mm made from 0.30 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 15x32 mm made out of 0.30 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 15 x 32 mm made of 0.30 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm) made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying tile in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using slotted cleats of size 25x35x1.6 mm fixed to ceiling with 8 mm dia and 45 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 15 mm of all T Sections shall be pre-painted with polyester baked paint. System Performance: NRC value of 0.20 (Minimum), light reflection > 85%, 100% humidity resistance and also having thermal conductivity <0.043 w/m 0 KC.

347.5 sqm

Technical notes unlock after sign-in

How specifying works

How to submit a proposal

  1. 01

    Create your supplier profile

    Verify a work contact and tell buyers what you supply.

  2. 02

    Review the protected brief

    Unlock buyer notes and protected reference files.

  3. 03

    Submit your proposal

    Share availability, lead time and your commercial offer privately.

Buyer identity and your proposal stay protected

You can qualify the request without seeing client, architect or exact site details. Your pricing stays private until you submit.

Buying instead of supplying?

Post a requirement and reach verified suppliers.

Post a request

3 BOQ lines

No commission to respond

Quote free